⚙ FMECA

Failure Mode, Effects and Criticality Analysis: the reference method for equipment reliability and for prioritising maintenance.

1What is FMECA?

FMECA (Failure Mode, Effects and Criticality Analysis; AMDEC in French) goes down to component level: for each function of a piece of equipment, it systematically lists the ways it can fail (failure modes), their effects on the system and their causes, then assesses the criticality of each mode. Without this final rating step, the method is called FMEA (AMDE in French).

The most common form of criticality is the Risk Priority Number (RPN), the product of three ratings: severity, occurrence and detection. It is the tool of choice for prioritising a preventive maintenance plan: rather than maintaining everything the same way, FMECA identifies where the effort should be focused.

Normative reference: IEC 60812 (2018 edition, adopted in France as NF EN IEC 60812) — Failure modes and effects analysis (FMEA and FMECA). The method was born in the US military (procedure MIL-P-1629 of 1949, then standard MIL-STD-1629A) before spreading to aerospace, automotive and the process industries.

2When to use FMECA

Three families of FMECA are generally distinguished, according to the object studied:

TypeObjectTypical use
Product (or design) FMECAA product under designMake a design reliable before it goes into production
Process FMECAA manufacturing processAvoid production defects and non-conformities
Equipment (or machine) FMECAAn existing piece of production equipmentBuild or optimise the preventive maintenance plan

FMECA is precise but costly: it is reserved for systems judged critical, often identified beforehand by a PHA. It analyses failures one by one and handles combinations of failures poorly; these are better covered by a fault tree.

3Definitions

TermDefinition
FailureLoss of the ability of an item to perform a required function (EN 13306, maintenance terminology). It is the event: the component stops fulfilling its function.
Failure modeThe observable manner in which the failure shows itself (e.g. “loss of flow”, “leak”, “stuck open”). A single component can have several distinct failure modes, each analysed separately.
CauseThe physical or operational origin that triggers the failure mode (e.g. “wear”, “clogging”, “power supply fault”).
EffectThe consequence of the failure mode on the function, the system or the user (e.g. “production stoppage”, “alarm triggered”).
A simple rule to avoid confusing mode and cause: the failure mode answers “what happens?”, the cause answers “why?”.

4Before you start: model the system

FMECA relies on a prior breakdown of the facility into systems, functions and components: this breakdown gives the rows of the FMECA worksheet (one component × one function × one failure mode per row). See the cross-cutting topic Facility modelling, shared with PHA, HAZOP and bow-tie.

5FMECA step by step

  1. Define the scope, the objectives and the rating scales before the first session: scales are not negotiated row by row.
  2. Break down the system into components and functions (see modelling above).
  3. List the failure modes of each function (e.g. “fails to start”, “leak”, “seizure”).
  4. Describe the effects of each mode on the system and its environment.
  5. Identify the possible causes of the failure mode.
  6. Rate severity, occurrence, detection and compute the RPN (see following sections).
  7. Define corrective measures (prevention, protection) for modes above the chosen threshold.
  8. Re-rate after measures and track the implementation of actions.
Sorting the worksheet by descending RPN immediately reveals the failure modes to treat first: this is the most direct use of the method.

6Rating risk in FMECA

The general principles of risk rating (matrix, scales, before/after measures) are common to all methods — see the cross-cutting topic Rating a risk. FMECA stands apart with its three metrics. IEC 60812 does not set a single scale: each organisation defines its own. 1-to-10 scales are common in automotive, 1-to-4 or 1-to-5 scales in industrial maintenance. The example below uses a 1-to-5 scale:

Metric135
Severity (S)Minor — minor disruption, no injurySerious — serious injury, prolonged stoppageCatastrophic — multiple fatalities, destruction
Occurrence (O)Very rare — < once / 10,000 hOccasional — once / 100 hVery frequent — > once / h
Detection (D)Very high — near-certain detection before effectsModerate — detection possible but uncertainVery low — not detectable before occurrence
Detection is the only inverted metric: a value of 1 is good (the failure is almost always detected in time), a value of 5 is bad (no means of detection) — see the dedicated section below.

7The Detection parameter

Detection (or non-detection) measures the ability to detect the failure mode or its cause before it produces its effects, not the ability to notice the failure once it has occurred. This is what makes it specific to FMECA: neither the PHA nor the bow-tie uses it as such; they reason in terms of barriers.

LevelMeaningTypical means of detection
1 — Very highNear-certain detection before effectsContinuous sensor + alarm + redundancy
2 — HighProbable detectionRegular automatic check
3 — ModerateDetection possible but uncertainPeriodic check
4 — LowHard to detectManual visual inspection
5 — Very lowNot detectable before occurrenceNo means of detection
Improving detection is often the quickest lever for lowering the RPN: adding a sensor generally costs less and takes less time than reducing the occurrence of a mechanical failure.

8The criticality index (RPN)

The RPN (Risk Priority Number; IPR in French) is a simple product:

RPN = Severity × Occurrence × Detection

With three metrics rated from 1 to 5, the RPN ranges from 1 to 125 (from 1 to 1,000 with 1-to-10 scales). The resulting level guides the prioritisation of the maintenance plan. Example thresholds, to be adapted to each organisation:

RPNLevel
1 – 20Negligible
21 – 40Minor
41 – 60Significant
61 – 100Critical
101 – 125Unacceptable
A moderate RPN can hide a severe scenario: a severity of 5 with occurrence and detection at 1 gives an RPN of 5, while the consequence, if it occurs, remains catastrophic. IEC 60812 points out these limitations of the RPN and presents other criticality approaches (notably a severity × occurrence matrix); in automotive, the 2019 AIAG-VDA handbook replaced the RPN with an “Action Priority” (AP). In practice, many approaches add a simple rule: any row at maximum severity is reviewed individually, whatever its RPN.

9Prevention and protection measures

TypeDefinitionActs onExample categories
PreventionReduces the probability that the failure mode occursOccurrenceScheduled preventive maintenance, component redundancy, operator training, choice of more resistant materials
ProtectionLimits or detects the effects once the failure mode has startedDetection / SeverityAutomatic detection (sensor + alarm), emergency shutdown device, safety relief valve, personal protective equipment (PPE)
A prevention measure acts before the failure mode appears, a protection measure acts after: the same distinction as the one used in the bow-tie between barriers on the cause side and barriers on the consequence side.

10Example: a drinking-water treatment plant

The Polyodos demonstration data set (drinking-water treatment plant, fictitious data) covers three systems — Pumping (raw water suction/discharge), Chemical treatment (neutralisation, flocculation, disinfection) and Storage (treated water and reagents) — with a 5-row FMECA worksheet, rated before measures:

#SystemComponentFailure modeEffectsCauses SODRPN
1PumpingCentrifugal pump P-101Loss of flow Insufficient downstream treatment, low-flow alarm Clogged suction strainer, impeller wear S3 O3 D2 18Negligible
2—Electric motor M-101Spurious trip Pumping stops, treated-water production cut off Thermal overload, power supply fault S4 O2 D1 8Negligible
3Chemical treatmentChlorine dosing unit D-201Chlorine overdosing Non-compliant water (chlorination by-products), risk of mucous membrane irritation pH sensor drift, dosing valve stuck open S4 O2 D2 16Negligible
4—Agitator A-201Agitator stops (shaft seized) Poor mixing, chlorination dead zones Foreign body in the tank, failed bearing S2 O2 D3 12Negligible
5StorageDrain valve V-301Spurious opening Uncontrolled draining of the 500 m³ tank, flooding of the downstream area Pneumatic actuator fault, operator error S4 O1 D2 8Negligible
FMECA worksheet — drinking-water treatment plant, fictitious data (before measures)

Reading the result and action plan

All RPNs remain below the threshold of 20: on this criterion alone, no row would be a priority. The additional severity rule changes the picture, because three rows are at S4:

RankFailure modeS × O × DRPNWhy treat itAction selectedAfter measures
1Loss of flow (P-101)3 × 3 × 218Highest RPN, highest occurrenceMonthly strainer cleaning (prevention) and weekly flow measurement (detection)3 × 2 × 1 = 6
2Chlorine overdosing (D-201)4 × 2 × 216High severity, health impactTo be defined in session: pH sensor check, high threshold on residual chlorine—
3Spurious trip (M-101)4 × 2 × 18High severity, but detection already very goodIndividual review, no immediate action—
4Spurious opening (V-301)4 × 1 × 28High severity, very low occurrenceIndividual review, no immediate action—

Row 1, the most critical in RPN terms, drops from 18 to 6 thanks to two measures: one reduces occurrence (3 → 2), the other improves detection (2 → 1). This example is handled in Polyodos, from worksheet to Word report. See the Industrial risks demo or try Polyodos free for 30 days.

11Common mistakes

MistakeWhy it is a problem
Confusing failure mode and causeThe mode is what fails (“leak”), the cause is why (“worn seal”): swapping them makes the worksheet inconsistent and the corrective actions poorly targeted.
Over-rating detection out of optimismOverestimated detection hides a real risk: a “hard to detect” mode must stay rated as such until a detection device is actually in place.
Changing scales during the studyScales debated row by row make RPNs incomparable with one another: fix them before the first session.
Forgetting to re-rate after measuresWithout an after-measures RPN, it is impossible to check that the corrective action really reduced criticality, or to justify its effectiveness in an audit.
Relying on the overall RPN aloneMaximum severity combined with low occurrence can give a moderate RPN while remaining catastrophic if it does occur: do not ignore high-severity rows because of an acceptable RPN.

12Further reading