1Why model before analysing
Before listing a single hazard or failure mode, you need to know what you are talking about: which system, which function, which component. Facility modelling sets out this breakdown once, so that every method that follows uses it in the same way.
It brings three benefits:
- consistency: a given component has the same name in the PHA, the FMEA and the HAZOP, so results can be cross-referenced;
- completeness: you can see at a glance which parts of the facility have not yet been analysed;
- study maintenance: when the facility changes, you know which analysis rows to revisit.
2Systems, functions, components
| Level | Definition | Example |
|---|---|---|
| System | A coherent part of the facility, bounded by its inputs and outputs | Pumping station, storage unit, packaging line |
| Function | What the system must do, expressed with an action verb | Pump raw water, maintain pressure, shut down on fault |
| Component | The hardware or software element that performs one or more functions | Pump, valve, pressure sensor, PLC |
Distinguishing functions from components is useful: a failure is analysed on the component, but its effects are measured on the function lost. One component can serve several functions, and one function can rely on several components.
For HAZOP, nodes (sections of the facility studied one at a time) and their parameters (flow, pressure, temperature, level), to which the guide words are applied, are added.
3What each method uses
| Method | Modelling level used |
|---|---|
| PHA | Systems and equipment, to locate each hazard |
| FMEA | Components and functions: a failure mode per component, and its effect on the function |
| HAZOP | Nodes and parameters |
| BowTie, fault tree | Components and functions as causes or barriers |
4Choosing the right level of detail
The right level depends on the question being asked and on how far the project has progressed:
- at the preliminary design stage, a PHA only needs the main systems;
- an FMEA goes down to the replaceable component (the pump, not each of its parts, except for the manufacturer's own study);
- a HAZOP is carried out on detailed drawings (piping and instrumentation diagrams).
5Example: a pumping station
Fictitious example: a drinking-water pumping station, modelled for a PHA and then an FMEA.
| System | Functions | Components |
|---|---|---|
| Pumping | Pump raw water; maintain the required flow | Pumps P1 and P2 (redundant), variable-speed drive, non-return valve |
| Reservoir | Store water; prevent overflow | Tank, level sensor, isolation valve |
| Control system | Control the pumps; shut down on high level | PLC, operator interface, high-high level switch |
The FMEA starts from each component: the failure "level sensor stuck" causes loss of the function "prevent overflow", unless the independent high-high level switch takes over. Modelling makes this redundancy visible even before rating.
In Polyodos, the "Modelling" page of the Technical or Industrial Risks module holds this breakdown (systems, functions, components, and nodes and parameters for HAZOP). PHA, FMEA and HAZOP rows refer to it, and deleting an element removes the link without erasing the analysis rows. See the Industrial risks demo or try Polyodos free for 30 days.
6Common mistakes
| Mistake | Why it is a problem |
|---|---|
| Modelling in too much detail from the outset | Hundreds of components before the first analysis: the study gets bogged down and the overall picture is lost. |
| Confusing function and component | "Pump" is not a function. Without explicit functions, you cannot say what the failure causes to be lost. |
| A different breakdown for each method | PHA and FMEA results can no longer be cross-referenced, and the same equipment is analysed twice under two names. |
| Forgetting utilities and the control system | Electricity, compressed air, PLCs: their failures often affect several systems at once. |
| Not updating after a modification | The study then describes a facility that no longer exists. |
7Further reading
Learn: the online course Industrial risks on aurorisk.com.