๐Ÿงฉ Facility modelling

Break a facility down into systems, functions and components before analysing it: the shared structure on which PHA, FMEA, HAZOP and BowTie analyses rely.

1Why model before analysing

Before listing a single hazard or failure mode, you need to know what you are talking about: which system, which function, which component. Facility modelling sets out this breakdown once, so that every method that follows uses it in the same way.

It brings three benefits:

2Systems, functions, components

LevelDefinitionExample
SystemA coherent part of the facility, bounded by its inputs and outputsPumping station, storage unit, packaging line
FunctionWhat the system must do, expressed with an action verbPump raw water, maintain pressure, shut down on fault
ComponentThe hardware or software element that performs one or more functionsPump, valve, pressure sensor, PLC

Distinguishing functions from components is useful: a failure is analysed on the component, but its effects are measured on the function lost. One component can serve several functions, and one function can rely on several components.

For HAZOP, nodes (sections of the facility studied one at a time) and their parameters (flow, pressure, temperature, level), to which the guide words are applied, are added.

3What each method uses

MethodModelling level used
PHASystems and equipment, to locate each hazard
FMEAComponents and functions: a failure mode per component, and its effect on the function
HAZOPNodes and parameters
BowTie, fault treeComponents and functions as causes or barriers

4Choosing the right level of detail

The right level depends on the question being asked and on how far the project has progressed:

Rule of thumb: go down one level as long as the elements have different failure modes, consequences or barriers. Stop as soon as they behave the same way.

5Example: a pumping station

Fictitious example: a drinking-water pumping station, modelled for a PHA and then an FMEA.

SystemFunctionsComponents
PumpingPump raw water; maintain the required flowPumps P1 and P2 (redundant), variable-speed drive, non-return valve
ReservoirStore water; prevent overflowTank, level sensor, isolation valve
Control systemControl the pumps; shut down on high levelPLC, operator interface, high-high level switch

The FMEA starts from each component: the failure "level sensor stuck" causes loss of the function "prevent overflow", unless the independent high-high level switch takes over. Modelling makes this redundancy visible even before rating.

In Polyodos, the "Modelling" page of the Technical or Industrial Risks module holds this breakdown (systems, functions, components, and nodes and parameters for HAZOP). PHA, FMEA and HAZOP rows refer to it, and deleting an element removes the link without erasing the analysis rows. See the Industrial risks demo or try Polyodos free for 30 days.

6Common mistakes

MistakeWhy it is a problem
Modelling in too much detail from the outsetHundreds of components before the first analysis: the study gets bogged down and the overall picture is lost.
Confusing function and component"Pump" is not a function. Without explicit functions, you cannot say what the failure causes to be lost.
A different breakdown for each methodPHA and FMEA results can no longer be cross-referenced, and the same equipment is analysed twice under two names.
Forgetting utilities and the control systemElectricity, compressed air, PLCs: their failures often affect several systems at once.
Not updating after a modificationThe study then describes a facility that no longer exists.

7Further reading

Learn: the online course Industrial risks on aurorisk.com.