1What is LOPA?
LOPA (Layer Of Protection Analysis) is a semi-quantitative method for estimating the frequency of an accident scenario. You start from the initiating event frequency, multiply it by the probability of failure on demand (PFD) of each independent protection layer (IPL) placed between the cause and the consequence, and compare the result with a target frequency:
f_residual = f_initiating × ∏ conditional factors × ∏ PFD(IPL)
The method was formalised by the CCPS (Center for Chemical Process Safety, part of AIChE) in Layer of Protection Analysis: Simplified Process Risk Assessment (2001), since supplemented by further CCPS guidelines on initiating events, IPLs and conditional modifiers. IEC 61511 (functional safety of safety instrumented systems for the process industry) lists it in Part 3 among the methods for determining the safety integrity level (SIL).
LOPA sits between qualitative analysis, such as the HAZOP that identifies the scenarios, and a full quantitative risk assessment. It is rigorous enough to justify a numerical risk level and fast enough to be applied to the most severe scenarios of a HAZOP or a hazard study.
2Key concepts: initiating event, IPL, PFD, conditional factors
| Concept | Definition |
|---|---|
| Initiating event | The cause that triggers the scenario: failure of a control loop, human error, equipment rupture, loss of a utility. It is expressed as a frequency, per year. |
| Enabling condition | A state that must be present for the initiating event to lead to the scenario, for example the fraction of the year during which the plant is in a given operating phase. It multiplies the initiating frequency. |
| Conditional modifier | A probability that applies after the loss of containment: probability of ignition, probability that a person is present in the area, probability that the exposure is fatal. It is used only when the consequence under study requires it. |
| IPL (Independent Protection Layer) | A device, system or action able on its own to prevent the scenario from reaching the consequence, independent of the initiating event and of the other IPLs of the same scenario. |
| PFD (Probability of Failure on Demand) | The probability that an IPL fails to perform its function when it is called upon. A PFD of 0.01 corresponds to a risk reduction factor of 100. |
| Target frequency | The maximum tolerable frequency for the consequence, set by the organisation or by the applicable regulatory framework, often graded by severity. |
To be counted as an IPL, a measure must be:
- independent of the initiating event and of the other IPLs: no shared sensor, logic solver, power supply or operator;
- effective: able to stop the scenario, in time, for the cause considered;
- auditable: its design, testing and maintenance are documented, so that the PFD claimed can be verified.
Commonly used orders of magnitude for PFD, to be justified for each site: properly sized and maintained pressure relief valve, 10-2; operator response to an alarm, with a procedure, training and sufficient response time, 10-1; basic process control system (BPCS) loop, 10-1; safety instrumented function, according to its SIL.
3The LOPA method, step by step
- Select the scenario from a HAZOP, a PHA or a hazard study: one initiating event and one specific consequence.
- Assess the severity of the consequence and derive the target frequency to be met.
- Estimate the initiating event frequency, per year, from generic data or the site’s operating experience.
- Apply enabling conditions and conditional modifiers where they are relevant and justified.
- Identify the IPLs actually in place and check each one for independence, effectiveness and auditability. Other safeguards are listed but not credited.
- Assign a PFD to each IPL.
- Calculate the residual frequency and compare it with the target frequency.
- If a gap remains, add or strengthen an IPL, often a safety instrumented function whose required SIL is derived from the gap, then recalculate.
4LOPA and SIL
When the existing IPLs are not enough, the remaining gap gives the PFD required of the safety instrumented function (SIF) to be added:
PFD_required = f_target ÷ f_residual without the SIF
For a function that is demanded infrequently (IEC 61511 “low demand” mode), the SIL is read from the average PFD:
| SIL | Average PFD | Risk reduction factor |
|---|---|---|
| SIL 1 | 10-2 to less than 10-1 | over 10 up to 100 |
| SIL 2 | 10-3 to less than 10-2 | over 100 up to 1,000 |
| SIL 3 | 10-4 to less than 10-3 | over 1,000 up to 10,000 |
| SIL 4 | 10-5 to less than 10-4 | over 10,000 up to 100,000 |
5Example: overpressure of a process vessel
A vessel containing a flammable hydrocarbon is fed through a valve controlled by the basic process control system. Scenario studied: the pressure control loop fails, the pressure rises, the vessel ruptures, the released material ignites and an operator present in the area is fatally injured. Fictitious data:
| Item | Value | Justification |
|---|---|---|
| Target frequency (fatality) | 10-6 /yr | Fictitious organisational criterion for a fatal accident |
| Initiating event: control loop failure | 0.1 /yr | Common generic value for a BPCS loop |
| Modifier: probability of ignition | 0.5 | Volatile material, possible ignition sources |
| Modifier: operator present in the area | 0.5 | Area occupied half of the shift |
| IPL 1: high-pressure alarm and operator response | PFD 0.1 | Sensor separate from the control loop sensor, written procedure, sufficient response time |
| IPL 2: pressure relief valve | PFD 0.01 | Sized for this case, periodically tested |
Calculation:
| Step | Operation | Result |
|---|---|---|
| Frequency after modifiers | 0.1 × 0.5 × 0.5 | 2.5 × 10-2 /yr |
| After IPL 1 (alarm and operator) | 2.5 × 10-2 × 0.1 | 2.5 × 10-3 /yr |
| After IPL 2 (relief valve) | 2.5 × 10-3 × 0.01 | 2.5 × 10-5 /yr |
| Comparison with the target | 2.5 × 10-5 > 10-6 | Not acceptable: gap of a factor of 25 |
| Required PFD of an additional SIF | 10-6 ÷ 2.5 × 10-5 | 0.04, i.e. a risk reduction factor of 25: SIL 1 |
| With a SIF of PFD 0.02 (feed cut-off on high-high pressure) | 2.5 × 10-5 × 0.02 | 5 × 10-7 /yr: acceptable |
Two remarks. Since the control loop is the initiating event, it cannot also be credited as an IPL. And the alarm counts only because its sensor is separate from the control loop sensor: with a shared sensor, a sensor failure would be both the initiating event and the loss of the alarm.
In Polyodos, the Industrial risks module includes a LOPA page that performs this calculation (initiating frequency, conditional factors, IPL PFDs, residual frequency compared with the target, required SIL) and can import scenarios from the hazard study or the HAZOP while keeping the link to their source. See the Industrial risks demo or try Polyodos free for 30 days.
6Common mistakes
| Mistake | Why it is a problem |
|---|---|
| Counting a preventive measure as an IPL | A measure that acts before the initiating event reduces its frequency: it belongs in the initiating frequency, not as an IPL. An IPL acts afterwards, to stop the cause from escalating into the consequence. |
| Ignoring common-cause failures | Two layers that share a sensor, a power supply or the same root cause are not independent: their PFDs cannot validly be multiplied. |
| Overcrediting human intervention | An operator action counts as an IPL only if detection and response time are compatible with the scenario’s dynamics, with a documented procedure and training. |
| Counting the control system twice | If the cause is a BPCS failure, another function of the same BPCS is not independent. IEC 61511 also limits to 10 the risk reduction that can be claimed for a BPCS layer not designed to the standard. |
| Stacking conditional modifiers | Each probability must be justified and match the consequence under study. Optimistic modifiers piled on top of each other artificially lower the frequency and the required SIL. |